Calibration tests are standard procedures applied to sensors not eliminated by screening tests . 校準(zhǔn)試驗(yàn)是對(duì)篩選試驗(yàn)中未被淘汰的傳感器進(jìn)行試驗(yàn)的標(biāo)準(zhǔn)測(cè)試程序。
During calibration test weights are compared with appropriate standards 校正過(guò)程中,測(cè)試砝碼將與適當(dāng)?shù)臉?biāo)準(zhǔn)進(jìn)行比較。
Calibration test equipment 校準(zhǔn)檢驗(yàn)置
Inquiring into calibration test of standard steel bottle and calculation of total deformation value 標(biāo)準(zhǔn)鋼瓶標(biāo)定試驗(yàn)及全變形值計(jì)算探討
Specification for radio disturbance and immunity measuring apparatus and methods - radio disturbance and immunity measuring apparatus - antenna calibration test sites for 30 mhz to 1 000 mhz 無(wú)線電干擾和抗擾測(cè)量?jī)x器和方法規(guī)范.無(wú)線電干擾和抗擾測(cè)量?jī)x器. 30mhz至1000mhz的天線校準(zhǔn)試驗(yàn)裝置
Specification for radio disturbance and immunity measuring apparatus and methods - part 1 - 5 : radio disturbance and immunity measuring apparatus - antenna calibration test sites for 30 mhz to 1 000 mhz 無(wú)線電干擾和抗擾的測(cè)量設(shè)備和方法的規(guī)范.第1 - 5部分:無(wú)線電干擾和抗擾的測(cè)量設(shè)備. 30 mhz至1 000 mhz的天線校正試驗(yàn)裝置
5 . the methods of temperature - correcting on copper cylinders and copper spheres are discussed . the method of unitive temperature - correcting on plastic pressue - measuring elements is put forward for the first time . large quantities of quasi - dynamic calibration tests in different temperatures are carried out on the dropper - hammer hydraulic dynamic pressure calibration device and the unitive temperature - correcting formula which accords with the traditional correcting method is got 在落錘液壓動(dòng)標(biāo)裝置上組織了多批次的銅柱、銅球高低溫準(zhǔn)動(dòng)態(tài)校準(zhǔn)試驗(yàn),探討了建立溫度誤差統(tǒng)一修正公式的可行性,建立了測(cè)壓銅球,測(cè)壓銅柱符合我國(guó)傳統(tǒng)修正方法的溫度統(tǒng)一誤差修正公式。
In the paper , through the calibration test of ground load , the relationship between outputs of electrical resistance of strain gauges and the external load applied on the structure has been gotten , and then the load history can directly be deduced from the measured strain history . so the fatigue load can be compiled 本文所建立的應(yīng)變法實(shí)測(cè)疲勞載荷,其主要方法是通過(guò)進(jìn)行地面加載標(biāo)定實(shí)驗(yàn),確定所設(shè)計(jì)應(yīng)變電橋輸出量與結(jié)構(gòu)上作用的外載荷之間的關(guān)系,再由實(shí)測(cè)應(yīng)變歷程直接得到載荷歷程的方法。
3 . a series of quasi - dynamic calibration tests by varying the pressure pulse width for the < t > 3 . 5 x 8 . 75mm pillar copper cylinders and o 4 . 763mm copper spheres are done on the dropper - hammer hydraulic dynamic pressure calibration device . by means of data analysis , the regulations of pulse width ' s effect on the two types of plastic pressure - measuring elements are obtained 3利用落錘液壓動(dòng)標(biāo)裝置組織了3 . 5 8 . 75mm柱形銅柱、 4 . 763mm銅球的變脈寬準(zhǔn)動(dòng)態(tài)校準(zhǔn)試驗(yàn),通過(guò)試驗(yàn)數(shù)據(jù)處理,獲得了兩種型號(hào)塑性測(cè)壓器件的脈寬影響規(guī)律。